In a clean room, contamination does not only come from the air. It comes from surfaces, materials, and movement. Every element of the building envelope — walls, ceilings, and floors — is part of the contamination control system. The floor is no exception.
A standard raised access floor is not suitable for a clean room environment. The materials, the joints, the finishing — everything has to respond to a set of technical requirements that conventional systems simply cannot meet.
Electrostatic control: a non-negotiable requirement
In pharmaceutical manufacturing, microelectronics, and precision research facilities, electrostatic discharge (ESD) can destroy components, compromise processes, and put personnel at risk. The floor finishing must dissipate static charge in a controlled, measurable way — not occasionally, but consistently, across the entire surface and throughout the building’s lifetime.
GAMAFLOR Full Steel with ESD conductive vinyl finishing provides permanent, verifiable electrostatic dissipation. Not a coating applied on top. A factory-bonded finish that is part of the panel itself.
Zero particle emission
Clean rooms are classified by the number of particles present in the air per cubic meter — from ISO Class 1 to ISO Class 9. Any material that generates particles under normal use is incompatible with those environments.
GAMAFLOR Full Steel panels — two electrowelded steel sheets pressure-injected with lightweight cement — have 0% moisture absorption and do not emit particles under load or movement. The plenum below remains as clean as the space above.
Total access to the plenum, without contamination risk
In clean rooms with underfloor air distribution (UFAD), the plenum is part of the air supply system. Filtered air enters through the plenum and rises through the floor. Any intervention — cable routing, maintenance, reconfiguration — must be possible without compromising the air quality of the space.
GAMAFLOR panels allow total access to the plenum. Panels can be lifted individually, work can be carried out, and the system can be restored without generating dust, debris, or structural disruption.
Chemical resistance
In pharmaceutical and biotech environments, the floor may be exposed to cleaning agents, disinfectants, and chemical compounds applied regularly and at high concentration. The finishing must resist these without degradation, without joint failure, and without generating secondary contamination.
A system designed for demanding environments
Specifying a raised access floor for a clean room is not a catalogue decision. It requires understanding the ISO classification of the space, the type of process it will host, the ESD requirements of the equipment, and the air management strategy of the building.
At Polygroup Raised Access Floor, we work with architects, engineers and project managers from the earliest stages of the project to define the most suitable system — based on the real demands of the space, not the standard specification.